EPEVER SOLAR Cost CONTROLLER Set up: TRACER AN Sequence CONTROLLE
EPEVER SOLAR Cost CONTROLLER Set up: TRACER AN Sequence CONTROLLE
Blog Article
The EPEVER Tracer AN Series Solar Charge Controller is really a very economical photo voltaic controller designed for off-grid photo voltaic methods. Dependant on multiphase synchronous rectification technology, it makes sure optimized Power conversion and process balance for an array of photovoltaic (PV) purposes.
Essential Features from the EPEVER Tracer AN Series Controller
The Tracer AN sequence utilizes EPEVER Solar Charge Controller engineering for remarkable photo voltaic energy harvesting. Vital features contain:
Multiphase Synchronous Rectification (MSR) for improved Strength conversion.
Innovative MPPT Algorithm with >ninety nine% performance.
Twin-Stage Charging for Increased battery life.
Liquid crystal display Display with real-time data checking.
Multiple Load Manage Modes which include manual and timer.
Complete Electronic Protections against overcharging, over-discharging, short circuits, and reverse polarity.
Step-by-Step Guide to Establishing the EPEVER Tracer AN Sequence Controller
1. Unboxing and Getting ready the Controller
Make sure all components are included: Tracer AN device, temperature sensor, interaction cables, and consumer guide.
Verify the model range and voltage scores match your photo voltaic panel and battery requirements.
2. Mounting the Charge Controller
Find a well-ventilated, dry locale near the battery lender.
Secure the Tracer AN controller using the delivered mounting brackets.
Retain suitable clearance for heat dissipation.
3. Wiring the Photo voltaic Cost Controller
Caution: Always stick to suitable basic safety protocols and make sure the program is powered off before connecting factors.
Phase 1: Connect the battery terminals to the demand controller (beneficial to optimistic, unfavorable to negative).
Action two: Connect the photo voltaic panel array to the PV enter terminals.
Step 3: Link the load terminals if using a direct load relationship.
Action 4: Double-Examine all connections for polarity and tightness.
4. Configuring the Controller Settings
Energy about the controller by connecting the battery very first.
Make use of the LCD Show to navigate the configurations menu.
Configure:
Battery Form: AGM, GEL, Flooded, Lithium.
Charging Parameters: Absorption voltage, float voltage.
Load Management Modes: Guide, timer, mild Management.
5. Checking and Knowledge Logging
The Tracer AN Series supports serious-time checking using the MT50 distant meter.
Knowledge could be logged via the RS485 interaction port working with program for example Solar Station Computer system.
Distant monitoring is achievable Together with the EPEVER WiFi module.
6. Troubleshooting Prevalent Concerns
Situation one: No Ability Output
Check out battery voltage and connections.
Verify PV panel voltage exceeds battery voltage.
Concern two: Above-Voltage Safety
Confirm the photo voltaic array’s voltage score.
Regulate technique parameters if necessary.
Situation 3: No Battery Charging
Inspect PV wiring for continuity.
Confirm MPPT configurations within the menu.
Benefits of the Tracer AN Series with MSR Engineering
The multiphase synchronous rectification technology ensures:
Greater Performance: Diminished energy losses through conversion.
Enhanced Dependability: Secure overall performance underneath variable loads.
More time Battery Life: Regular and exact charging profiles.
Conclusion
The EPEVER Photo voltaic Demand Controller with multiphase synchronous rectification visit here engineering is really an Outstanding option for optimizing solar energy generation and extending battery lifetime. By subsequent the above mentioned set up manual, end users can be certain greatest effectiveness and program longevity.